16S1P EVE Grade-A 3.2V 314Ah LFP cells with 2A active balancing for sustained capacity retention across the full service life
51.2V 314Ah 16kWh LiFePO4 Floor-Standing Battery — Manufacturer Direct Supply for Distributor & EPC Orders
Balder Power BP16314 16kWh Floor-Standing LiFePO4 Battery with LED SoC Indicator
The BP16314 16kWh floor-standing battery is built for residential solar self-consumption, villa and farm backup power, off-grid energy systems, and telecom room storage applications.
Configured in 16S1P with 314Ah LiFePO4 cells and a 200A BMS featuring 2A active balancing, this battery delivers consistent energy output, wireless remote monitoring, and multi-layer protection in a single floor-standing steel cabinet.
With a nominal energy of 16.07kWh, RS485 / RS232 / CANbus triple-protocol communication, Bluetooth and WiFi monitoring, a front-panel LED SoC indicator strip, and support for up to 15 units in parallel.
-
51.2V 314Ah LiFePO4 battery with 16.07kWh nominal energy
-
-
200A BMS with RS485 / RS232 / CANbus communication and DIP-selectable address (1–15)
-
Bluetooth and WiFi dual wireless monitoring, iOS & Android app support
-
Front-panel LED strip for at-a-glance SoC status without app or inverter access
-
200A continuous discharge with 500μs short-circuit trip at 1200A threshold
-
Supports up to 15 units in parallel — scalable to approximately 240kWh per 51.2V bank
-
CE, IEC62619, CB, UN38.3 certified | M8 copper terminals | 200A 1P air switch included
-
Floor-standing steel cabinet with wheels for on-site positioning, 910 × 450 × 260mm
Descripción del Producto
Across residential solar markets in Europe, Southeast Asia, and Latin America, time-of-use tariff structures are shifting the core value proposition of home battery storage away from capacity alone and toward reliability of delivery across the full service life. A 16kWh battery that holds 90% of its rated capacity after three years of daily cycling is worth more to the homeowner than a 16kWh unit that degrades to 80% after 18 months because cell-to-cell voltage drift went uncorrected. The BP16314 is a 51.2V 314Ah LiFePO4 floor-standing battery designed with this long-view in mind, pairing a 2A active balancing circuit with wireless remote monitoring so that cell-level health is tracked and corrected continuously — not discovered late during a service call. It suits daily solar self-consumption across residences, villas, and small commercial premises equally well, and operates reliably in off-grid farm installations and telecom room environments where a degraded pack cannot simply be swapped out on short notice.
The 16S1P prismatic cell stack is governed by a 200A BMS carrying RS485, RS232, and CANbus ports on the front panel, which hands the BP16314 a direct communication path into Deye, Growatt, Sol-Ark, Victron, and the broader field of mainstream hybrid inverter platforms without any intermediate adapter. Parallel to the inverter data link, the BMS streams live SoC, pack voltage, current, and temperature readings over both Bluetooth and WiFi at the same time — meaning the homeowner’s app, the installer’s remote session, and the inverter display all draw from the same live BMS data concurrently rather than one blocking another. A front-panel LED strip adds a third access point for SoC status: one that requires no device, no network, and no inverter menu — a practical reference during warehouse receiving checks, installation staging, and any on-site maintenance where pulling out a phone or navigating an inverter display adds unnecessary steps.
For distributors running installer networks across multiple sites, the BP16314’s combination of wireless remote access and DIP-selectable RS485 addressing (positions 1–15, position 0 reserved) changes the economics of after-sales support. When a site reports that the battery “isn’t holding a full charge,” the first diagnostic step is a remote review of the BMS balancing log rather than a scheduled site visit — the 2A active circuit leaves a correction trail that shows whether cell divergence has developed, how quickly, and whether it tracks a charging pattern issue or a cell-level change. At fleet scale, the difference between resolving a complaint remotely in 20 minutes and dispatching a technician for half a day is where per-unit margin on a battery like the BP16314 is actually preserved.
Parámetros técnicos
| Parámetro | Especificación |
|---|---|
| Modelo de batería | BP16314 (BP16314-16S1P-51.2V 314A-1.0) |
| Química | LiFePO4 (fosfato de hierro y litio) |
| System Voltage | 51.2V nominal | Operating range: 40–58V |
| Rated Capacity (Ah) | 314Ah typical / 310Ah minimum |
| Energy (kWh) | ~16.07kWh nominal |
| Configuración de celda | 16S1P (16 series, 1 parallel) |
| BMS Rating | 16S 200A |
| Active Balancing | 2A balancing current | Activates at 3.35V/cell threshold |
| Communication Protocol | RS485 / RS232 / CANbus (three ports, front panel) |
| RS485 Address Range | DIP-selectable 1–15 (address 0 reserved) |
| Wireless Monitoring | Bluetooth + WiFi dual wireless | iOS & Android app |
| Local SoC Display | Front-panel LED strip SoC indicator |
| Compatible Inverter Brands | Deye, Growatt, Sol-Ark, Victron and other RS485/CAN hybrid inverters |
| Corriente máxima de descarga continua | 200A (limiting) |
| Discharge OC Protection | 100±9A two-stage; 1200A short-circuit trip within 500μs |
| Corriente de carga máxima | 200A max; 100A standard (0.5C) |
| Modo de carga | CC-CV (Constant Current – Constant Voltage) |
| Voltaje de corte de carga | 56–58V |
| Voltaje de corte de descarga | 40–44.8V |
| Cell Overcharge Protection | 3.65 ± 0.025V (release: 3.45V) |
| Cell Over-discharge Protection | 2.2 ± 0.1V (release: 2.4V) |
| Charge Temperature Range | 0°C a 45°C |
| Discharge Temperature Range | -20°C a 55°C |
| Temperatura de almacenamiento | 23 ± 2°C recommended | 45–75% RH |
| Ciclo de vida | 6000+ cycles at 0.5C standard charge/discharge |
| Output Terminal | M8 copper terminal (P+/P–); 200A fence through-type terminal |
| Air Switch | 200A 1P internal air switch |
| Cabinet Construction | Steel enclosure with wheels for positioning; φ16mm round soft switch |
| Certificaciones | CE, IEC62619, CB, UN38.3, MSDS |
| Dimensions (W×D×H mm) | 910 × 450 × 260mm |
| Peso (kg) | ~115kg (including bracket) |
| Primary Application | Residential and light-commercial floor-standing home energy storage |
| Tipo de suministro | Factory-direct wholesale supply for distributor stock and EPC project orders |
Características y ventajas
✅ 🔌 Triple-Protocol BMS Communication — RS485, RS232, and CANbus on One Pack
The BP16314 BMS exposes RS485, RS232, and CANbus ports simultaneously on the front panel, giving installers a direct path into the communication bus of Deye, Growatt, Sol-Ark, Victron, and other hybrid inverter platforms without an external protocol converter. Each unit carries a DIP-switch for RS485 address selection (1–15; address 0 reserved), which is set before energizing the pack and must not duplicate another unit on the same bus. The BMS reports live SOC, pack voltage, current, and ambient temperature continuously across the active protocol, so inverter commissioning is confirmed by watching live data appear on the inverter display — not by assuming a powered connection is also a communicating one.
✅ ⚡ 200A Continuous Output with 500μs Short-Circuit Response
The 16S 200A BMS is rated for 200A continuous limiting current, with discharge over-current protection staged at 100±9A across two threshold levels before a 500-microsecond short-circuit trip at 1200A. Release from short-circuit protection requires a charge event rather than automatic retry, which prevents repeated fault cycling in wiring faults that haven’t been cleared. This staged protection topology — threshold-1 → threshold-2 → hard trip — is the same architecture used in grid-tied commercial packs because it distinguishes sustained overload from brief transient current, reducing nuisance trips on motor-start loads like HVAC compressors and well pumps without sacrificing fault isolation speed.
✅ 🧩 DIP-Addressable RS485 Parallel Architecture — Up to 15 Units per Bus
Up to 15 BP16314 units can share a single RS485 communication bus using the front-panel DIP address switch, scaling from one 16kWh residential pack to a 240kWh+ light-commercial array on a single 51.2V battery bank. All units in a parallel string operate within a consistent voltage window — 40–44.8V discharge cut-off, 56–58V charge ceiling — so pack-to-pack voltage mismatch at energization is bounded by the shared BMS threshold rather than left to passive cell chemistry. For distributors, this means a single SKU and a single wiring diagram covers residential through small commercial deployments, which simplifies installer training and reduces per-site ordering errors.
Embalaje y entrega
Embalaje seguro y conforme
Para garantizar el tránsito seguro de mercancías peligrosas de clase 9, cada batería está protegida con Lana perlada de alta calidad (espuma EPE) y encerrado en Cajas de cartón certificadas por la ONU. Para envíos a granel, utilizamos materiales resistentes. Paletas de madera contrachapada o plástico Envuelto en film retráctil, totalmente compatible con las regulaciones de envío internacionales.
Opciones de envío globales (Incoterms)
Admitimos condiciones de envío flexibles para adaptarnos a las necesidades de su negocio, incluyendo: FOB, CIF y DDP (Puerta a Puerta con impuestos incluidos).
- Por mar: La opción más económica para pedidos al por mayor.
- Por aire/expreso: Entrega rápida de muestras (DHL/UPS/FedEx).
- En tren: Servicio CR Express confiable para los mercados de Europa y Asia Central.
Plazo de producción
Nuestro plazo de entrega varía según la personalización del producto:
| Tipo de producto | Muestras | Pedido al por mayor |
|---|---|---|
| Modelos estándar | 15 - 20 días | 25 - 30 días |
| Modelos personalizados | 30 - 40 días | 30 - 40 días |
Preguntas frecuentes
Q1: Which inverters are confirmed compatible with the BP16314, and how do I select the correct protocol at commissioning?
The BP16314 BMS carries RS485, RS232, and CANbus ports, covering the communication bus used by Deye, Growatt, Sol-Ark, Victron, and other mainstream hybrid inverters. During commissioning, set the inverter’s lithium battery protocol to match the BP16314 BMS output mode — your inverter installation manual will list the available protocol options. Once connected, confirm a live handshake by checking that the inverter display populates real-time SOC, pack voltage, and current values rather than a static or zero reading.
Q2: The inverter shows “battery connected” but SOC is stuck at 0% or doesn’t update — what’s causing this?
This is almost always a protocol mismatch, wiring polarity error, or reserved address conflict rather than a hardware fault. Check three things in order: first, confirm the inverter protocol setting matches the BMS communication mode; second, verify RS485 A/B lines or CAN-H/CAN-L polarity aren’t reversed at the cable connector; third, check that the DIP address switch on the battery is not set to position 0, since address 0 is reserved on this BMS and will not respond on the bus.
Q3: What is the container-load pricing structure, and can I order a sample unit before committing to a full shipment?
Sample units are available for evaluation before a container-load commitment, with shorter lead times than a full production run since they draw from existing or near-ready stock. Container-load pricing is volume-tiered — contact us with your target quantity and delivery port for a current ex-works and CIF price breakdown. OEM labeling is available from confirmed minimum volumes.
Q4: What are the physical installation requirements for the BP16314 in a residential setting?
The cabinet measures 910×450×260mm and weighs approximately 115kg with bracket. It ships with wheels for positioning during installation — once the final location is confirmed, the unit is stabilized via the mounting bracket. Plan floor clearance around the front panel for access to the RS485/RS232/CAN ports, DIP address switch, φ16mm soft power switch, and the 200A air switch. The 200A fence through-type terminal and M8 copper output terminals (P+/P–) are also front-accessible, so keep 400–500mm of working clearance in front of the unit.
Q5: How many BP16314 units can I parallel together, and what’s the maximum system capacity in one 51.2V bank?
Up to 15 units can be connected in parallel on one RS485 communication bus, using DIP address positions 1–15 (address 0 is reserved and must not be used). Each unit contributes approximately 16.07kWh, giving a maximum bank capacity of around 240kWh at the 51.2V nominal level. All paralleled units must share the same charge/discharge voltage window — 56–58V charge ceiling, 40–44.8V discharge cut-off — so confirm your inverter’s battery bank voltage settings match before energizing a multi-pack array.
Q6: How is cycle life validated for this battery, and what operating conditions support the 6000-cycle rating?
The 6000+ cycle figure is based on 0.5C standard charge/discharge cycling, which means charging at 100A and discharging at the equivalent rate against the 314Ah nominal capacity. Operating within the defined charge temperature window (0°C to 45°C) and discharge window (-20°C to 55°C), and avoiding sustained operation at the voltage cut-off boundaries, are the primary conditions that support this cycle life. Cycle life degrades faster when packs are held at full charge voltage for extended periods or operated repeatedly near the over-discharge cut-off — both are avoidable through inverter charge window settings.